The Tricuspid Valve Annular Geometry and Dynamics –A Clinical Experiment in Pigs

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Brieflands

Abstract

T forskning, PalleJuulJensens Boulevard, Aarhus N, Denmark Background Tricuspid annuloplasty rings are routinely applied clinically. An optimal ring should reconstruct the valve annulus to its original configuration and adapt natural annular motion. However, there is still a lack of knowledge for a rational design. The aim of this study was to investigate the correlation between tricuspid valve annular geometry and deformational forces out-of-plane (substudy 1) and in-plane (substudy 2) using a porcine model