Success Rate of Airway Devices Insertion: Laryngeal Mask Airway Versus Supraglottic Gel Device

AuthorAlireza Pournajafianen
AuthorMahzad Alimianen
AuthorFaranak Rokhtabnaken
AuthorMohammadreza Ghodratyen
AuthorMozhgan Mojrien
OrcidAlireza Pournajafian [0000-0002-6464-3713]en
Issued Date2015-04-01en
AbstractBackground: The main important method for airway management during anesthesia is endotracheal intubation. Laryngeal mask airway (LMA) and supraglottic gel device (I-Gel) are considered alternatives to endotracheal tube. Objectives: This study sought to assess the success rate of airway management using LMA and I-Gel in elective orthopedic surgery. Patients and Methods: This single-blinded randomized clinical trial was performed on 61 ASA Class 1 and 2 patients requiring minor orthopedic surgeries. Patients were randomly allocated to two groups of LMA and I-Gel. Supraglottic airway placement was categorized into three groups regarding the number of placement attempts, i.e. on the first, second, and third attempts. Unsuccessful placement on the third attempt was considered failure and endotracheal tube was used in such cases. The success rate, insertion time, and postoperative complications such as bleeding, sore throat, and hoarseness were recorded. Results: In the I-Gel group, the success rate was 66.7% for placement on the first attempt, 16.7% for the second, and 3.33% for the third attempt. In the LMA group, the success rates were 80.6% and 12.9% for the first and second attempts, respectively. Failure in placement occurred in four cases in the I-Gel and two cases in LMA groups. The mean insertion time was not significantly different between two groups (21.35 seconds in LMA versus 27.96 seconds in I-Gel, P = 0.2). The incidence of postoperative complications was not significantly different between study groups. Conclusions: I-Gel can be inserted as fast as LMA with adequate ventilation in patients and has no major airway complications. Therefore, it could be a good alternative to LMA in emergency airway management or general anesthesia.en
DOIhttps://doi.org/10.5812/aapm.22068en
KeywordLaryngeal Masken
KeywordMechanical Ventilationen
KeywordGeneral Anesthesiaen
PublisherBrieflandsen
TitleSuccess Rate of Airway Devices Insertion: Laryngeal Mask Airway Versus Supraglottic Gel Deviceen
TypeResearch Articleen

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
17438-pdf.pdf
Size:
121.09 KB
Format:
Adobe Portable Document Format
Description:
Article/s PDF