Preoperative CT Morphology and Tumor Extracellular Volume Fraction for Identifying Air-Space Spread in 1 - 3 cm Solid Lung Adenocarcinoma

Loading...
Thumbnail Image

Journal Title

Journal ISSN

Volume Title

Publisher

Brieflands

Abstract

Background: Spread through air spaces (STAS) is associated with recurrence after limited resection of lung adenocarcinoma; however, reliable preoperative assessment remains challenging. Objectives: This study investigated whether routine computed tomography (CT) morphology and tumor CT-derived extracellular volume fraction (CT-ECV) contribute to the preoperative identification of STAS in 1 - 3 cm CT-solid lung adenocarcinomas. Patients and Methods: This retrospective study included 104 surgically resected tumors, of which 53 (51.0%) showed STAS. Twelve prespecified preoperative variables were analyzed using least absolute shrinkage and selection operator (LASSO) logistic regression with repeated nested stratified five-fold cross-validation. A full-cohort stratified 10-fold analysis was performed to describe variable retention at the minimum-error and one-standard-error penalty levels. Out-of-fold discrimination and calibration were assessed using the area under the receiver operating characteristic curve (AUC), Brier score, calibration intercept and slope, and a bootstrap confidence band. Interobserver agreement and CT-ECV remeasurement reproducibility were assessed using Cohen's kappa, the intraclass correlation coefficient (ICC), and Bland-Altman analysis. Results: At the minimum-error penalty, LASSO retained peripheral ill-defined opacity, tumor CT-ECV, and vascular convergence; at the one-standard-error penalty, only peripheral ill-defined opacity was retained. The out-of-fold AUC was 0.632 (95% confidence interval [CI], 0.522 - 0.737), and the mean fold-specific AUC was 0.628 ± 0.122. Calibration was limited (Brier score, 0.237; calibration intercept, 0.016; calibration slope, 0.645). Interobserver agreement for peripheral ill-defined opacity was almost perfect (kappa, 0.919; 95% CI, 0.834 - 0.981). Region-of-interest-based CT-ECV remeasurement on the same CT examinations showed good relative agreement (ICC, 0.890) but wide absolute limits of agreement (−8.62% to 8.91%). Conclusion: In surgically resected 1 - 3 cm CT-solid lung adenocarcinoma, peripheral ill-defined opacity was the most stable contributor to STAS assessment, whereas CT-ECV was less consistent. Modest discrimination and calibration limit clinical utility and support the need for validation in larger, multicenter cohorts before application beyond this population.

Description

Keywords

Citation

Collections

Endorsement

Review

Supplemented By

Referenced By