Successful Detachable Coil Embolization of Iatrogenic Superior Vena Cava Penetration by Central Venous Catheter: A Case Report

AuthorByung Jin Parken
AuthorJae Kyu Kimen
AuthorHyoung Ook Kimen
AuthorNam Yeol Yimen
AuthorYang Jun Kangen
Issued Date2017-10-31en
AbstractIatrogenic injuries of the superior vena cava (SVC) are infrequent but could bring severe complications. Perforation of the SVC may result in massive hemorrhage and hemodynamic instability. We report the case of a 58-year-old female with a right hemothorax after left subclavian central venous catheter (CVC) placement. Penetration of the SVC can be managed by coil embolization through left subclavian CVC. As a result, this injury was successfully managed. To our knowledge, this is the first report of management of SVC penetration using coil embolization.en
DOIhttps://doi.org/10.5812/iranjradiol.63481en
KeywordCentral Venous Cathetersen
KeywordVena Cavaen
KeywordSuperioren
KeywordEmbolizationen
KeywordTherapeuticen
KeywordRadiologyen
KeywordInterventionalen
KeywordHemothoraxen
PublisherBrieflandsen
TitleSuccessful Detachable Coil Embolization of Iatrogenic Superior Vena Cava Penetration by Central Venous Catheter: A Case Reporten
TypeCase Reporten

Files